below are alarm information usually happen on cnc machine, this alarm will appear on cnc monitor and will show to you to fix immediately,this alarm maybe different with other cnc machine depend on brand and monitor unit
WORD
ERROR (T code error)
LOW
OIL LEVEL (low oil level)
SPINPLE
FAULT (spindle fault)
SPINDLE
ALARM (spindle alarm)
EXTERNAL
EMG STOP (emergency stop button pressed)
AC
NOT READY (AC disc is not ready)
SPINPLE
LUBE FAULT (spindle lubrication failure)
T
CODE ERROR (T code error, illegal T code)
M
CODE ERROR (M code error, illegal M code)
SERVO
NOT READY (servo not ready)
NC
NOT READY (NC not ready)
TURRET
FAULT (turret fault)
TURRET
LIMIT (turret limit)
DC
24V OPEN (DC 24 disconnect)
+
24V NOT READY (+ 24V not ready)
GRAR
DRIFT
PLEASE
AXIS RETURN HOME (axis not returned to zero)
PLEASE
DRUM RETURN HOME (magazine does not return to zero)
AIRPRESSFAILURE
UNCL
TOOL FALL
AIR
PRESSURE DROP (Compressed air pressure too low)
CLAMP
TOOL FALL
DRUM
NOT PARKED (library is not in the original value)
X
ZERO POINT NOT REACHED (X axis not returned to zero)
Y
ZERO POINT NOT REACHED (Y-axis does not return to zero)
Z
ZERO POINT NOT REACHED (Z-axis does not return to zero)
4TH
ZERO POINT NOT REACHED (4th axis not returned to zero)
X
AXIS OVERTRAVL (X axis limit)
Y
AXIS OVERTRAVL (Y-axis limit)
Z
AXIS OVERTRAVL (Z axis limit)
COUNTER
SWITCH REEOR (count switch fault)
MASTERT
RANSFER OVER TEMP (main transformer overheating)
Z
AXIS NOT AT FIRST REF POSITION (Z axis not at first reference point)
SPINDLE
ORIENTATION FALLURE (spindle orientation failure)
TOOL
DESENT OR TOOL DATA REEOR (tool data error)
PLEASE
UNLOAD THE TOOL ON SPRINELK (Please remove the knife on the spindle)
PLEASE
LOAD TOOL ON APINDLE (Please attach the knife on the spindle)
A
AXIS UNCLAMP FAIL (A axis release failed)
A
AXIS CLAMP FAIL (A-axis clamp failure)
DRUM
OUT TO APRONDLEIS FALL (Tool changer swing position change)
MG
SWING OVERLOAD (magazine swing overload)
DRUM
BACK PARK IS FALL (Toolbox goes back to its original position)
TURRENT
MOTOR1 OVERLOAD (magazine moving motor overload)
COOLANT
MOTOR OVERLOAD (cooling pump overload)
DRUM
ATC FAULT (automatic tool change failed)
TOOLS
UNLOCKED (tool not locked)
BATTERY
ALARM (battery alarm)
DRUM
POSITION SWITCH ERROR (Tool magazine position detection switch fault)
DRUM
NOW NOT AT PARK (magazine is not in its original position)
IT
DANGOU TO MOVE DRUM
POT
UO FAILOR POT NOT AT UP POSITION (Tool set not in horizontal
position)
POT
DOWN FAIL
IT
IS DANGOR TO MOVE ARM (Robot Prohibition)
THE
SPINDLE STATU IS ERROR (spindle status error)
ARM
MOTOR OR ARM SWITCH FALL (robot or robot switch failure)
CENTER
LUBRICATION FALL (center lubrication failure)
THE
WORK NOT CLAMPED (workpiece not clamped)
AUTO
TOOL CHANGE FAULT (automatic tool change failed)
TOOL
DATA OUT OF RANGE (instruction tool number out of range)
THE
ORDER TOOL NOW IN SPINDLE (target tool on spindle)
THE
THREE SPINDLE SWITCH FAULT (Proximity switch on spindle)
THE
CENTER COOLANT IS LOWER (Tool internal cooling pump level is too low)
DRUM
RETURN 1 # POSITION FAULT
SPINDLE
OVERLOAD (spindle overload)
Pay
attention to our WeChat public number shukongzhpngguo, get more CNC
technical articles.
TURRENT
MOTOR OVERLOAD (cutter rotor motor overload)
CHIP
CONVEYER OVERLOAD
HARD
LIMIT OR SERVO ALARM (hard limit or servo alarm)
NO
LUB OIL (no oil)
INDEX
HEAD UNLOCKED (split head unlocked)
MT
NOT READY (machine is not ready)
MG
OVERLOAD (magazine overload)
LUB
EMPTY (oil free)
AIR
PRESSURE
COOLANT
NOT READY (not ready for cooling)
LUBE
EMPTY (low oil mist, low oil level)
LUB
PRESSURE LOW (low lubrication pressure)
CONVEY
VERLOAD
LUB
OVERLOAD (Lubrication Overload)
LUBE
PRESSURE LOW (low oil mist pressure)
SERIAL
SPINDLE ALARM (serial spindle alarm)
NC
BATTERY LOW ALARM (NC battery low alarm)
MAGAZINE
MOVE LIMIT SWITCH ERROR
SPINDLE
TOOL UNLAMP POSITION LIMIT SWITCH ERROR
MAGAZINE
NOT IN POSITION OR SENSOR ERROR
AIR
PRESSURE LOW ALARM (low pressure alarm)
MOTOR
OVERLOAD (motor overload)
T
CODE> MAGAZINE TOOLS
T
CODE <1 ERROR
5TH
AXIS HARDWARE OVERTRAVER LIMIT ERROR
DOOR
IS OPENED (open the door)
LUB
PRESSURE SWITCH ERROR (oil pressure switch error)
SPINDLE
OIL COOLANT UNIT ERROR
SPINDLE
LOAD ABNORMAL (spindle load exception)
TRANSDUCER
ALARM (sensor alarm)
BED-HEAD
LUBRICATE OFF (bedside lubrication off)
EMG
OFF
HYDRAULIC
CHUCK PRESS LOW (hydraulic chuck pressure low)
HYDRAULIC
TAIL PRESS LOW (hydraulic tailstock pressure low)
LUB
0IL LOW (low oil pressure)
TURRET
CODE ERROR (turret code error)
TURRET
RUN OVERTIME (turret run timeout)
MANUAL
HANDLE INTERRUPT
TRY
TO RUN SPINDLE WHILE CHUCK NOT LOCK
TRY
TO RUN SPINDLE WHILE TAIL NOT LOCK
SPINDLE
NEUTRAL GEAR
MAGAZINE
ADJUST
HYDRAULIC
NOT RUN
SAFETY
DOOR BE OPENED
SAFETY
DOOR NOT CLOSE
NOT
ALL AXIS HAVE GONE BACK REF
IN
ADJUST, IGNORE GOING BACK REF
AFTER
EXCHANGE TOOL, CYCLE START
ATC
MOTOR QF16 OFF
X
AXIS IS LOCKED (X axis is locked)
Y
AXIS IS LOCKED (Y axis locked)
Z
AXIS IS LOCKED (Z axis is locked)
A
AXIS IS LOCKED (A axis is locked)
SPINDLE
MOTOR FAN QF26 OFF (spindle motor fan QF26 closed)
Pay
attention to our WeChat public number shukongzhpngguo, get more CNC
technical articles.
SPINDLE
ORIENTATION INCOMPLETE (spindle positioning is not complete)
M
FUNCTION NOT COMPLETE (M function can not be completed)
SPINDLE
NOT IN GEAR POSITION (gear is not in spindle position)
SPINDLE
NOT CHANGED TO LOW GEAR (spindle does not become low)
SPINDLE
NOT CHANGED TO HIGH GRAR (the spindle does not become upscale)
MAG
NOT BACKWARD
SPINDLE
TOOL NOT CLAMP
SPINDLE
TOOL NOT UNCLAMP
MAG
NOT IN POSITION
MAG
DOES NOT ROTATE
MAG
DOES NOT STOP RUNNING
A
AXIS HAVE NOT CLAMPED
A
AXIS HAVE NOT UNCLAMPED
SET
D499 = 1, "MAG.JOG" SWITCH ON
HYDRAULIC
MOTOR QF7 OFF (hydraulic motor QF7 closed)
HYDRAULIC
TEMPRETURE HIGH (high hydraulic pressure)
HYDRAULIC
FILTER BLOCKED (hydraulic filter block)
HYDRAULIC
OIL LEVEL LOW (low hydraulic oil level)
HYDRAULIC
FAN QF8 OFF (hydraulic fan QF8 closed)
HELIX
CONYER QF9 OR QF10 OFF
CHAIN
CONYER QF11 OFF
COOLANT
MOTOR QF12 OFF (coolant motor QF12 closed)
COOLNT
LEVEL LOW, CYCLE STOP AFTER 20 MINUTES
INNER
COOLANT BLOCK (internal cooling jam)
SPINDLE
COOLANT MOTOR QF14 OFF (spindle coolant motor QF14 closed)
INNER
COOLANT QF13 OFF (internal coolant QF13 closed)
MAG
MOTOR QF15 OFF
CABINET
COOLANT EQUIP QF20 OFF
OIL
GATHER QF24 OFF
AIR
PRESSURE LOW
SPINDLE
COOLANT MOTOR FAULT (spindle cooler motor fault)
LUB.OIL
IS LOW (low oil)
DOOR
OPEN (door open)
FRONT
DOOR (R) OPEN (front door open)
LEFT
DOOR OPEN (left door open)
LUBRICATION
OIL QF23 OFF (Lubricant QF23 closed)
LUBRICATION
PRESS LOW (low oil level)
IN
ADJUST, MAG CAN NOT EXCHANGE T (in the adjustment, the magazine can
not exchange T)
NOT
ALL DOOR CLOSED (the door is not closed all)
IN
M06, MAG NOT READY (in M06, the magazine is not ready)
MAGAZINE
NOT READY (magazine is not ready)
POCKET
NOT HORIZANTAL
IN
M06, Z NOT BACK TO 2ND REF
IN
M06, Z AXIS NOT IN PSW1
ATC
NOT IN ZERO POSITION
SPINDLE
ORIENTATION UNCOMPLETE
POCKET
NOT HOR./MAG NOT BCKWRD
POCKET
NOT VER./MAG NOT FORWRD
UNCLAMP
TOOL HAS NOT COMPLETED
CLAMP
TOOL HAS NOT COMPLETED
AIM
TOOL NO. IS WRONG
MAG
NOT BACKWARD
AFTER
RETRACT, SET RTBACK OFF
Z
NOT IN PSW2, FORBID ATC RUNNING
D499
EQUAL 1
MAG.JOG
SOFT SWITCH IS ON
Z
NOT IN PSW2, FORBID MAG FORWARD
CHEKE
SPINDLE MODULE ALARM
OIL
WATER SEPARATOR QF24 OFF
SET
THE SOFT SWITCH MAG.JOG OFF
SET
D499 TO 0 Set D499 to 0
K
PARAM ABOUT MAG SET IS WRONG K parameter setting error for MAG
MECHANICAL
BRAKE NOT RELEASED The machine brake is not released
MECHANICAL
BRAKE IS WRONG
PLEASE
ADD LUB.OIL Please add lubricant
PROBE
BATTERY VOLTAGE IS LOW Probe battery voltage is low
PROBE
IS ERR probe error
PARAMETER
WRITE ENABLE (parameter write enable)
PMC
EDIT ENABLE (PMC Edit enabled)
CHECK
LUB ROUTIN
SPINDLE
GEAR SIGNAL MISS Spindle gear signal disappears
T_CLAMPED_SIGNAL
MISS T clamping signal disappears
SP
OVERRIDE SWITCH DISCONNECTION The spindle override switch is open
FEED
OVERRIDE SWITCH DISCONNECTION Feedrate override switch
THE
TOTAL NUMBER OF POCKETS SET ERR
CHANGE
T STOPED BECAUSE NO AIR stopped due to lack of pressure exchange
THE
COOLANT WATER TOO LOW, ADD COOLANT WATER AT ONCE Cool water Less
water immediately
COOLANT
LEVEL LOW, ADD COOLANT WATER Low water level
PLEASE
REPLACE CNC BATTERY QUICKLY Please replace the CNC battery
immediately
Alarm information on CNC machine
Reviewed by Unknown
on
4:23 AM
Rating:
Nice blog and absolutely outstanding. You can do something much better but i still say this perfect.Keep trying for the best. chuông báo cháy hochiki
ReplyDeleteYour blog held my interest right to the very end, which is not always an easy thing to do!!
ReplyDeleteCustom CNC Machining
Service affordability should also be considered. The prices should match the product quality that you get in the end. Remember that the raw materials used can determine the service charge. Look at what materials the factory can handle and the needs you have before choosing the best you can afford. Rapid prototyping services
ReplyDeleteI should thank you for writing on this topic, very useful information you have given through this blog regarding education sector. I will visit again to get more information.
ReplyDeletecustom CNC machining
Informative share! I read your article, I liked it very much, you gave very good information about Commercial expresso machine.
ReplyDeleteCheck here
Visit here
Additional info
Thank you so much for sharing this blog with us. It provides a big collection of useful information. Great effort you put into it. A wonderful take.
ReplyDeletecnc machining quartz